Non-acidic leave-in treatment to cure boiler noise

Living with a noisy boiler is not only unpleasant, but it can also be inefficient. A number of factors can cause boiler noise, but it is most often caused by a thin layer of deposit on the heat exchanger. Sentinel X200 Noise Reducer is extremely effective in solving this problem, whilst simultaneously helping to restore boiler efficiency.

Key features

  • Reduces boiler noise
  • Helps restore boiler efficiency
  • Easy to handle
  • Simple to dose
  • Suitable for all metals including aluminium
  • Non-acid, non-corrosive
  • Manufactured under a quality system confirming to IOS9001

Available sizes

1L liquid X200L-12X1L-GB
10L liquid X200L-10L-DRUM
20L liquid X200L-20L-DRUM
275ml concentrate gel X200C-12X275ML-GB
400ml Rapid-Dose™ aerosol X200RD-12X400ML-GB

RAPID DOSE

Designed to make dosing in to the system quicker than ever.

Product Fact Sheet Safety Data Sheet

 

Features and Benefits

  • Quickest dosing means less time on the job
  • No need to drain or depressurise the system*
  • Adaptor included for application into Sentinel Eliminator®, radiator or boiler filling loop

*It is only necessary to release system pressure when it is above 2.3 bar.

CONCENTRATE

Slimline format to make dosing in to the system fuss free.

Product Fact Sheet Safety Data Sheet

 

Features and Benefits

  • Easy dosing means less time on the job
  • Smaller size enables easy storage
  • Controlled application using skeleton gun

Boiler noise is an inconvenience for homeowners and can be an indicator of an underlying problem with the central heating system such as system design or mechanical faults. Once these have been ruled out as the cause of boiler noise the most common cause is a thin layer of limescale or other deposit inside the boiler. Sentinel X200 Noise Reducer is a highly successful treatment for curing the problem.

It is a non-acid, leave-in treatment; a gentler but still highly effective solution to this common problem. Treating boiler noise caused by deposits with Sentinel X200 Noise Reducer will also help to restore boiler efficiency.

 

1 litre, 1 400ml aerosol, or 1 275ml tube of Sentinel X200 Noise Reducer is sufficient to treat a typical domestic system of up to 10 radiators. Larger systems should be dosed with twice this amount.

Open Systems: Dose via F&E cistern, via a by-pass feeder or use a Sentinel Dosing Vessel.

When using concentrate gel, add directly to the heating system either via a radiator air bleed valve, or via the fill loop using the appropriate adaptor and a suitable caulk gun.

Sealed Systems: If the system is empty, add to any convenient point before filling. If full, use a Sentinel Dosing Vessel to inject via the filling loop or other access point.

When using concentrate gel, add directly to the heating system either via a radiator air bleed valve, or via the fill loop using the appropriate adaptor and a suitable caulk gun.

The information provided below enables compliance with the Control of Substances Hazardous to Health Regulations. 

  Sentinel X200 Noise Reducer Liquid

Sentinel X200 Concentrate Gel

Sentinel X200 Rapid Dose Aerosol

Stockcodes

X200L-12X1L-GB
X200L-10L-DRUM
X200L-20L-DRUM

X200C-12X275ML-GB X200RD-12X400ML-GB
About An aqueous solution of synthetic polymers, phosphonate and surfactant.

Appearance

Clear colourless liquid

Clear colourless liquid

N/A

Odour

Mild Mild Mild

Specific Gravity

1.01 (20°C)

1.03 (20°C)

1.04 (20°C)

pH in aqueous solution (1%)

7.5 (approx.)

7.5 (approx.)

7.7 (approx.)

Freezing Point

-1.5°C

-5°C

-1°C

Health Hazards
  • Not for use in potable water systems
  • Not considered hazardous to health
First Aid

Skin Exposure
Wash immediately with plenty of water. If irritation develops, seek medical attention.

Eye Exposure
Flush immediately with plenty of running water. Seek medical attention.

Ingestion
Rinse mouth with water. Do NOT induce vomiting. Seek medical attention.

Skin Exposure
Wash immediately with plenty of water. If irritation develops, seek medical attention.

Eye Exposure
Flush immediately with plenty of running water. Keep eyelids apart. Seek medical advice.

Ingestion
Rinse mouth with water. Do NOT induce vomiting. Seek medical advice.

Skin Exposure
Wash immediately with plenty of water. If irritation develops, seek medical attention.

Eye Exposure
Flush immediately with plenty of running water. Seek medical attention.

Ingestion
Rinse mouth with water. Seek medical attention.

Handling
  • Avoid contact with skin and eyes
  • Keep out of reach of children and animals
  • Wash out empty container thoroughly with water before disposal
  • Avoid contact with skin and eyes
  • Avoid breathing vapours
  • Keep out of reach of children and animals
  • Wash out empty container thoroughly with water before disposal
  • Avoid contact with skin and eyes
  • Keep out of reach of children and animals
  • Use only as directed
  • Contents of the can are under pressure and will discharge when attached to the connector
  • Ensure that the connector is securely attached to the heating system prior to mating with the can
  • It is only necessary to release system pressure when it is above 2.3 bar.
Storage
  • Keep container tightly closed
  • Store in cool, well ventilated area
  • Store in a cool, well ventilated area
  • Keep container tightly closed
  • Protect from freezing
  • Store in cool, well ventilated area
  • Pressurised container. Protect from sunlight and do not expose to temperatures exceeding 50°C
  • Do not pierce or burn, even after use
Spillage
  • Flush spillage plenty of water and wash to waste
  • Flush spillage with plenty of water and wash to waste
  • Not considered harmful to the environment
  • Flush spillage with plenty of water and wash to waste
Fire/Explosion Risks Non-flammable